2005 Pontiac grand Prix. Engine dimension 3.8. Brand-new blower motor.Question:The blower motor quit working in mine "05 Pontiac cool Prix. Making use of my volt meter, I checked forvoltage at the blower. With the fan set to the highest setting, I witnessed 12 volts therefore I assumed the blower motorwas poor replaced it.

You are watching: 2005 pontiac grand prix blower motor problems

The brand-new motor ran for 5 secs then stopped. Still getting 12 V at highest setting and 6V at shortest fansetting. I"ve read that if the resistor go bad, the fan will certainly operate only at the highest speed, howevermine doesn"t operate at all. Any suggestions?


More concerns For...

pontiac cool prix

ANSWER:

Your system works a tiny different. No separate circuit for high only. The blower resistor / controlmodule controls every speeds, and also the ground for the blower- circuit 2150 BLK wire. Have to put the voltmeter, or far better yet a check light, in the blower connector. Check light will certainly light if you have power in andground. Sounds choose you probably won"t.

Sounds prefer the resistor / module is bad. Also check the plug on the for shed terminals. The modulealso has a floor behind the radio top top the overcome beam.

*

Question:1997 Pontiac cool Prix. Replaced seized blower motor and also faulty resistor.The blower engine works just on high mode, the reduced modes do not work and additionally its affect thedaytime control lights once blower speed is used.

Answer:Could you please give me a little an ext info. The blower motor was seized, and the resistor wasreplaced. Did either show any kind of signs the corrosion or discoloration in ~ the electric connectors? Anyother odd electrical problems prior to the replacement of this parts? any other details will it is in helpful.Thanks and also I will wait for her reply.

Visitor Reply:no corrosion at all on terminals what its doing is this problem was their prior to the blower andresistor to be replaced. The trouble was the DRL lights go off when blower motor switch is usedand go back on as soon as the switch is off. Also the blower motor just works in high mode after aslight delay. What I"m listening is the relays click in the work time driving light module as soon as theblower switch is used. Thanks any kind of questions allow me know. Thanks.

Answer:OK, ns think i uncovered something to be of help. ~ looking through several wiring diagrams, ns havefound that the Daytime running Lights Module and a power input to the a/c manage head sharethe same fuse (DIC/HVAC) there is likewise a DRL diode in the system. The module and the diodeare top top the lf. Side/under the dash.

See more: Who Was The White Fang Of The Hidden Leaf In The Naruto Anime?

We require to uncover out which component is click erratically. Supposedly there is some electric backfeeding walk on, and effecting the DRL/headlights. I wound doubt a faulty DRL module, butthe diode may be the initial problem, bring about the module walk bad. Hope this to be helpful. Let meknow what friend find.